UERSIS is UT thickness inspection software for drone ultrasonic surveys: it reads the Voliro or Flyability report and turns it into a record of the asset your client opens online.

A drone UT survey of a flare stack or tank ends with a vendor PDF: pages of readings, probe photos and A-scans, but no design thickness and no comparison with the last survey. Someone copies the numbers into a spreadsheet to work out loss and margin, then does it all again next year and hopes the point names line up. Your client gets a PDF built from a PDF, and the history of the asset lives in a folder.
Upload the Voliro or Flyability Inspector (Elios 3 UT) report and UERSIS reads it for you. It finds or creates the asset, stores every reading (failed ones included) and takes the probe photos and A-scans out of the PDF. A Voliro data export from the same day merges in and adds GPS, probe angle and calibration figures. On the next survey, points are matched by name and then by GPS within about 1.5 m, so the new readings land on the same points.
Enter the nominal wall and the minimum allowable once. Every point then gets its loss, its margin to minimum and a status: within limits, near minimum or below minimum. The wall thickness chart plots every reading against the nominal and minimum lines, and each reading shows its probe photo, its A-scan and its change since the last survey. With an earlier survey of the same asset, UERSIS also shows the worst corrosion rate and the remaining life.
Only your team sees the survey while it is in review. When you publish, your client sees the readings, the chart and the figures in your Hub, read-only. One click makes a branded PDF with the method and instrument, every reading, the points that need attention and a page per point with its photo and A-scan, compared against the earlier survey. The next survey of the asset picks up where this one left off.
Questions
Which UT reports can UERSIS import?
Voliro UT reports and Flyability Inspector (Elios 3 UT) reports as PDFs, plus Voliro CSV or JSON data exports, up to 200 MB a file. Readings from a hand gauge or another instrument cannot be imported.
How are corrosion rate and remaining life worked out?
Each point is compared with the same point on the previous survey of the asset, matched by name and then by GPS. The worst corrosion rate and the remaining life come from the points that got thinner between the two dates. Loss and margin use the nominal and minimum wall you enter, because vendor reports do not carry the design thickness.
Which plans include UT thickness?
Business and Enterprise include it, and Team can take it as its one included pick. Otherwise, on Solo and Team it is a $99 a month specialist module. Every plan starts with a 14-day free trial.